Currently viewing the dev server.

Tennessee Gas Pipeline Icon

RESTRICTIONS FOR 06-23-2025 ID1

Tennessee Gas Pipeline 1d ago

Source Link

All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  06/23/2025 11:53:12AM Notice End Date/Time:  06/24/2025 9:00:00am
Post Date/Time:  6/23/2025 11:53:12 AM Notice ID: 394987
Reqrd Rsp:  1 Rsp Date:  06/23/2025
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 06-23-2025 ID1
Notice Text:

Effective Intraday 1 Cycle (14:00) for the gas day of Monday, June 23, 2025 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR THE 500 LINE ONLY (SEGMENTS 527,529, 530, 534, 539, 542, 548, 860) FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

 

OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 245 AND STA 325 FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

 

 

METER RESTRICTIONS

·         GULF SOUTH/TGP Kiln Miss Exchange Receipt Meter (Pin 420383) - through approx 80% of SIPss increases due to operational concerns; 16,040 Dths

·         VCP/TGP Valley Crossing Allocation Delivery Meter (Pin 53608) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 8,958 Dths

·         NMP/TGP Gillrina Road Nueces Delivery Meter (Pin 47799) - through 100% of SIPss increases due to scheduled maintenance and nominations in excess of operational capacity; 8,159 Dths

·         ETP/TGP Wharton County Transport Ex Receipt Meter (Pin 411911) - through 100% of SIPss increases due to scheduled maintenance and nominations in excess of operational capacity; 25,160 Dths

·         MATTEXPR/TGP Bernard Creek Receipt Meter (Pin 56009) - through 100% of SA increases due to scheduled maintenance and nominations in excess of operational capacity; 14,067 Dths

·         TRANSCO/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through PIP increases due to operational concerns

SEGMENT RESTRICTIONS

·         STA 17 (Segment 117 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 16,385 Dths

·         STA 523 West (Segment 516 FH) - through approx 38% of SOP increases due to nominations in excess of operational capacity; 3,710 Dths

·         STA 860 South 500 Line (Segment 548 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity

·         STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 408,714 Dths

·         MLV 314 East (Segment 314 BH) - through approx 93% of SOP increases due to nominations in excess of operational capacity; 281,198 Dths

·         STA 315 (Segment 315 BH) - through approx 69% of SOP increases due to nominations in excess of operational capacity; 195,867 Dths

·         STA 317 (Segment 317 BH) - through approx 55% of SOP increases due to nominations in excess of operational capacity; 47,132 Dths

·         STA 321 (Segment 321 FH) - through approx 11% of SOP increases due to nominations in excess of operational capacity; 13,481 Dths

·         STA 325 (Segment 324 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 26,908 Dths

·         Z5 HC North (Segment 299 FH) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 310,151 Dths

·         STA 245 (Segment 245 FH) - through approx 99% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 429,510 Dths

·         STA 249 (Segment 249 FH) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 233,167 Dths

·         STA 261 Discharge East (Segment 261 FH) - through approx 94% of SOP increases due to nominations in excess of operational capacity; 81,918 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 314,067 Dths

LINEPACK RESTRICTIONS

·         No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service

·         No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service

·         Paybacks will be evaluated at each cycle and scheduled only if operationally feasible

 

 

STORAGE RESTRICTIONS

·         No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:

·         Northern MA (460018) storage field

·         Portland MA (460025) storage field

·         Portland PA (460020) storage field

·         Bear Creek PA (460017) storage field

·         No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:

·         Northern MA (460018) storage field (IS-MA)

·         Bear Creek PA (460017) storage field (IS-PA)

 

 

**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.

**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  06/23/2025 11:53:12AM Notice End Date/Time:  06/24/2025 9:00:00am
Post Date/Time:  6/23/2025 11:53:12 AM Notice ID: 394987
Reqrd Rsp:  1 Rsp Date:  06/23/2025
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 06-23-2025 ID1
Notice Text:

Effective Intraday 1 Cycle (14:00) for the gas day of Monday, June 23, 2025 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR THE 500 LINE ONLY (SEGMENTS 527,529, 530, 534, 539, 542, 548, 860) FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

 

OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 245 AND STA 325 FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

 

 

METER RESTRICTIONS

·         GULF SOUTH/TGP Kiln Miss Exchange Receipt Meter (Pin 420383) - through approx 80% of SIPss increases due to operational concerns; 16,040 Dths

·         VCP/TGP Valley Crossing Allocation Delivery Meter (Pin 53608) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 8,958 Dths

·         NMP/TGP Gillrina Road Nueces Delivery Meter (Pin 47799) - through 100% of SIPss increases due to scheduled maintenance and nominations in excess of operational capacity; 8,159 Dths

·         ETP/TGP Wharton County Transport Ex Receipt Meter (Pin 411911) - through 100% of SIPss increases due to scheduled maintenance and nominations in excess of operational capacity; 25,160 Dths

·         MATTEXPR/TGP Bernard Creek Receipt Meter (Pin 56009) - through 100% of SA increases due to scheduled maintenance and nominations in excess of operational capacity; 14,067 Dths

·         TRANSCO/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through PIP increases due to operational concerns

SEGMENT RESTRICTIONS

·         STA 17 (Segment 117 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 16,385 Dths

·         STA 523 West (Segment 516 FH) - through approx 38% of SOP increases due to nominations in excess of operational capacity; 3,710 Dths

·         STA 860 South 500 Line (Segment 548 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity

·         STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 408,714 Dths

·         MLV 314 East (Segment 314 BH) - through approx 93% of SOP increases due to nominations in excess of operational capacity; 281,198 Dths

·         STA 315 (Segment 315 BH) - through approx 69% of SOP increases due to nominations in excess of operational capacity; 195,867 Dths

·         STA 317 (Segment 317 BH) - through approx 55% of SOP increases due to nominations in excess of operational capacity; 47,132 Dths

·         STA 321 (Segment 321 FH) - through approx 11% of SOP increases due to nominations in excess of operational capacity; 13,481 Dths

·         STA 325 (Segment 324 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 26,908 Dths

·         Z5 HC North (Segment 299 FH) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 310,151 Dths

·         STA 245 (Segment 245 FH) - through approx 99% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 429,510 Dths

·         STA 249 (Segment 249 FH) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 233,167 Dths

·         STA 261 Discharge East (Segment 261 FH) - through approx 94% of SOP increases due to nominations in excess of operational capacity; 81,918 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 314,067 Dths

LINEPACK RESTRICTIONS

·         No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service

·         No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service

·         Paybacks will be evaluated at each cycle and scheduled only if operationally feasible

 

 

STORAGE RESTRICTIONS

·         No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:

·         Northern MA (460018) storage field

·         Portland MA (460025) storage field

·         Portland PA (460020) storage field

·         Bear Creek PA (460017) storage field

·         No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:

·         Northern MA (460018) storage field (IS-MA)

·         Bear Creek PA (460017) storage field (IS-PA)

 

 

**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.

**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.