TSP/TSP Name: 1939164-TENNESSEE GAS PIPELINE | Critical: Y |
Notice Type Desc (1): PIPELINE CONDITIONS | Notice Type Desc (2): CURRENT PIPELINE CONDITIONS |
Notice Eff Date/Time: 07/30/2025 3:40:02PM | Notice End Date/Time: 07/31/2025 9:00:00am |
Post Date/Time: 7/30/2025 3:40:02 PM | Notice ID: 395394 |
Reqrd Rsp: 1 | Rsp Date: 07/30/2025 |
Notice Stat Desc: INITIATE | Prior Notice: |
Subject: RESTRICTIONS FOR 07-30-2025 ID2 |
Effective Intraday 2 Cycle (18:00) for the gas day of Wednesday, July 30, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR THE 500 LINE AND ALL AREAS EAST OF STA 254 ON THE 200 LINE AND ALL AREAS EAST OF STA 325 ON THE 300 LINE FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· ATMOS-MS/TGP Shuqualak Ms Noxubee Delivery Meter (Pin 420320) - through 100% of SOP increases due to nominations in excess of operational capacity; 148 Dths
SEGMENT RESTRICTIONS
· STA 860 South 500 Line (Segment 548 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 426,098 Dths
· MLV 314 East (Segment 314 BH) - through approx 97% of SOP increases due to nominations in excess of operational capacity; 298,448 Dths
· STA 315 (Segment 315 BH) - through approx 76% of SOP increases due to nominations in excess of operational capacity; 205,011 Dths
· STA 317 (Segment 317 BH) - through approx 88% of SOP increases due to nominations in excess of operational capacity; 65,233 Dths
· MLV 330 (Segment 324 FH) - through approx 54% of SOP increases due to nominations in excess of operational capacity; 25,669 Dths
· Z5hc North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 266,850 Dths
· STA 245 (Segment 245 FH) - through SIPsp increases due to scheduled maintenance and nominations in excess of operational capacity
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
TSP/TSP Name: 1939164-TENNESSEE GAS PIPELINE | Critical: Y |
Notice Type Desc (1): PIPELINE CONDITIONS | Notice Type Desc (2): CURRENT PIPELINE CONDITIONS |
Notice Eff Date/Time: 07/30/2025 3:40:02PM | Notice End Date/Time: 07/31/2025 9:00:00am |
Post Date/Time: 7/30/2025 3:40:02 PM | Notice ID: 395394 |
Reqrd Rsp: 1 | Rsp Date: 07/30/2025 |
Notice Stat Desc: INITIATE | Prior Notice: |
Subject: RESTRICTIONS FOR 07-30-2025 ID2 |
Effective Intraday 2 Cycle (18:00) for the gas day of Wednesday, July 30, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR THE 500 LINE AND ALL AREAS EAST OF STA 254 ON THE 200 LINE AND ALL AREAS EAST OF STA 325 ON THE 300 LINE FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· ATMOS-MS/TGP Shuqualak Ms Noxubee Delivery Meter (Pin 420320) - through 100% of SOP increases due to nominations in excess of operational capacity; 148 Dths
SEGMENT RESTRICTIONS
· STA 860 South 500 Line (Segment 548 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 426,098 Dths
· MLV 314 East (Segment 314 BH) - through approx 97% of SOP increases due to nominations in excess of operational capacity; 298,448 Dths
· STA 315 (Segment 315 BH) - through approx 76% of SOP increases due to nominations in excess of operational capacity; 205,011 Dths
· STA 317 (Segment 317 BH) - through approx 88% of SOP increases due to nominations in excess of operational capacity; 65,233 Dths
· MLV 330 (Segment 324 FH) - through approx 54% of SOP increases due to nominations in excess of operational capacity; 25,669 Dths
· Z5hc North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 266,850 Dths
· STA 245 (Segment 245 FH) - through SIPsp increases due to scheduled maintenance and nominations in excess of operational capacity
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.